Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Orthopaedic Trauma ; (12): 498-504, 2023.
Article in Chinese | WPRIM | ID: wpr-992739

ABSTRACT

Objective:To evaluate our self-designed pubic symphysis orthotic compression anatomic plate (PSOCAP) in the treatment of fractures and dislocations around the pubic symphysis.Methods:A retrospective study was conducted to analyze the 16 patients with fracture or dislocation around the pubic symphysis who had been treated by our self-designed PSOCAP at Department of Traumatic Surgery, Center for Orthopaedic Surgery, The Third Hospital Affiliated to Southern Medical University from January 2021 to June 2022. There were 8 males and 8 females with an age of (41±19) years. According to the Tile classification for pelvic fractures, there were 3 cases of type B1, 2 cases of type B3, 1 case of type C1.2, 4 cases of type C1.3, 3 cases of type C2, and 3 cases of type C3. There were 8 cases of pubic symphysis separation and 8 fractures of the pubic ramus (2 ones at Nakatani zone Ⅰ and 6 ones at Nakatani zone Ⅱ). Time from injury to surgery was 16 (11, 53) days, ranging from 4 to 348 days. The fractures or dislocations around the pubic symphysis were exposed by the modified Stoppa approach, reduced with the assistance of PSOCAP and fixated with PSOCAP; the posterior pelvic ring was reduced and fixated by corresponding surgical methods. Recorded were the surgical time, intraoperative bleeding, postoperative quality of fracture reduction, surgical complications, and functional recovery at the last follow-up concerning the pelvic anterior ring.Results:Surgery went on successfully in the 16 patients. Their surgical time was (58±15) min, ranging from 40 to 90 min, and their intraoperative bleeding 85 (63, 150) mL, ranging from 50 to 250 mL. According to the Matta scoring, the fracture reduction was evaluated as excellent in 10 cases, as good in 3 cases and as fair in 3 cases. The (10±3)-month follow-up for the 16 patients revealed complete fracture union for all after (12±2) weeks. According to the Majeed scoring at the last follow-up, the pelvic function was evaluated as excellent in 5 cases, as good in 7 cases, and as fair in 4 cases. No such postoperative complications as fracture displacement or internal fixation failure occurred.Conclusion:Owing to the biplane and integrated structure, our self-designed PSOCAP can help reduce the fractures or dislocations around the pubic symphysis to achieve anatomical reduction and strong internal fixation, leading to good clinical efficacy.

2.
Chinese Journal of Trauma ; (12): 234-239, 2022.
Article in Chinese | WPRIM | ID: wpr-932232

ABSTRACT

Objective:To establish the classification system of sacroiliac joint dislocation with ipsilateral sacral wing fracture (SJDISWF), examine its reliability and evaluate the clinical application.Methods:A multi-center retrospective case series study was conducted to analyze the clinical data of 20 SJDISWF patients admitted to Third Affiliated Hospital of Southern Medical University, Honghui Hospital Affiliated to Xi′an Jiaotong University and Third Hospital of Hebei Medical University from January 2016 to December 2019. There were 8 males and 12 females, aged from 13-58 years[(34.7±13.2)years]. Based on the direction of sacral displacement, SJDISWF was divided into 3 types. Type I: the sacroiliac joint dislocated and the ipsilateral sacral wing fracture fragment was anteriorly prolapsed; Type II: the sacroiliac joint dislocated, the ipsilateral sacral wing fracture fragment was compressed or crushed, the anterior sacral foramen may fractured; Type III: the sacroiliac joint dislocated and the ipsilateral sacral wing fracture end was inserted into the sacral canal, causing an intra-sacral canal occupation. The reliability of the classification was performed based on the assessment results of two phases in four observers at 4-week intervals. Treatments were utilized based on the types I, II, III fractures, including anterior approach for open reduction and internal fixation, closed reduction and internal fixation or posterior approach for open reduction and internal fixation respectively. Postoperative fracture healing time was recorded. Quality of fracture reduction was graded according to Matta′s criteria. Majeed functional score was recorded at postoperative 3 months, 6 months and the final follow-up. Complications were detected as well.Results:The overall Kappa value of inter-observer reliability was 0.890. The overall Kappa value of intra-observer reliability was 0.854. There were 12 patients with type I, 7 with type II and 1 with type III. All patients went through the procedure uneventfully and were followed up for 6-36 months[(20.0±8.7)months]. All patients achieved clinical healing in 8-14 weeks[(10.2±1.7)weeks]. According to the Matta′s criteria for fracture reduction, the outcome was excellent or good in 83% (10/12) for type I, 71% (5/7) for type II and 0% (0/1) for type III, with the overall excellent rate of 75%. Majeed functional score was (74.6±5.2)points at postoperative 3 months and (84.4±5.8)points at postoperative 6 months ( P<0.01). According to Majeed functional score, the outcome was excellent or good in 75% (9/12) for type I, 100% (7/7) for type II and 0% (0/1) for type III at the final follow-up, with the overall excellent rate of 80%. There were no complications such as lateral femoral cutaneous nerve or sciatic nerve injury, lower extremity deep vein thrombosis, sacroiliac joint pain, failure of internal fixation or loss of fracture reduction during the follow-up. Conclusions:The SJDISWF classification has high reliability. The classification-oriented treatment strategy has achieved a relatively satisfactory restoration and functional recovery, indicating that the classification plays a certain role in guiding treatment selection for SJDISWF.

3.
Chinese Journal of Orthopaedics ; (12): 1426-1433, 2021.
Article in Chinese | WPRIM | ID: wpr-910732

ABSTRACT

Objective:To investigate the surgical technique and the clinical effects of direct posterior approach (DPA) with the fixation of percutaneous tunnel screw and plate for acetabular posterior comminuted fractures.Methods:Thirty-six cases with acetabular posterior comminuted fractures treated by this technique from January 2016 to July 2020 were retrospectively analyzed in this study. There were 28 males and 8 female, aged 42.0±12.1 (range 19-64) years. According to Letournel-Judet classification, there were 28 cases of transverse associated with posterior wall fractures, 6 cases of posterior column with posterior wall fractures and 2 cases of T shape with posterior wall fractures. DPA was adopted in prone position. The anterior and posterior column fractures of the acetabulum were reduced under direct vision and then fixed with percutaneous tunnel screw. Further, the posterior wall fractures of the acetabulum were reduced and fixed with plate and screws. The operation duration, intraoperative blood loss, incision length, fracture union time, fracture reduction quality, postoperative complications and hip function were recorded.Results:The incision was 9.8±1.2 (range 8-12) cm. The operation duration was 102.9±21.4 (range 65-145) min. Intraoperative bleeding was 214.0±116.9 (range 100-640) ml. Postoperative X-ray and CT examinations showed perfect reduction. All the patients were followed up for 20.9±9.2 (range 10-38) months. The fracture healing time was 4.6±1.0 (range 3-6) months. There was no patient with damaged superior gluteal nerve and blood vessel. There were 2 cases of femoral head cystic changes without pain in walking, 1 case of postoperative infection and bacteremia who was cured at 1 month after debridement and anti-infection treatment, 1 case of sciatic nerve injury but recovered at 3 months after operation, and 1 case of heterotopic ossification at 3 months after surgery without affecting hip motion. According to the Matta's criteria, the reduction quality of the acetabular fracture was rated as excellent in 28 cases, good in 6 cases, fair in 2 cases. According to the modified Merle D'Aubigné and Postel scoring system, hip joint function was excellent in 24 cases, good in 10 cases and fair in 2 cases.Conclusion:DPA approach can directly reduce acetabular posterior comminuted fractures through a minimal incision. Combined with the technique of percutaneous tunnel screw, it displays great advantages of less trauma and with good clinical effects.